DCM-042

AC/DC Current clamp meter,DCM-042
dcm-042-all.jpg
Features:






  • AC/DC Current Clamp meter ( DCM-042)

    Specifications:
    AC Current (accuracy: at the center of CT)
    Range: 0 to 600.0A
    Accuracy: ±(2.0%rdg+5dgts) on 20Hz to 100Hz
    ±(6.0%rdg+5dgts) on 100Hz to 400Hz
    Resolution: 0.1A
    AC Voltage
    Range: 0 to 600.0V
    Resolution: 0.1V
    Accuracy: ±(1.0%rdg+5dgts) on 20 to 100Hz
    ±(6.0%rdg+5dgts) on 100 to 400Hz
    Input impedance: 1M?
    DC Current (accuracy: at the center of CT)
    Range: 0 to 600.0A
    Accuracy: ±(2.0%rdg+5dgts)
    Resolution: 0.1A
    DC Voltage
    Range: 0 to 600.0V
    Resolution: 0.1V
    Accuracy: ±(1.0%rdg+5dgts)
    Input impedance: 1M?
    Resistance (Autorange)
    Range: 0 to 999.9?, 1000 to 9999?
    Accuracy: ±(1.5%rdg+5dgts)
    Resolution: 0.1?/1?
    Frequency
    Range: 20 to 400.0Hz
    Resolution: 0.1Hz
    Sensitivity: 5Vrms TTL signal,
    ?5A @20 to 100Hz, ?10A @100 to 400Hz
    Accuracy: ±(0.5%rdg + 5dgts)
    Diode Test
    Accuracy: ±(3.0%rdg+3dgts)
    Resolution: 0.001V
    Test current: 0.2mA
    Test Voltage: <3.0V
    Continuity
    Audible indication: less than 30?
    Capacitance
    Range: 0 to 999.9µF
    Resolution: 0.1µF
    Accuracy: ±(5.0%rdg + 10dgts)
    Temperature (K-Type Thermocouple)
    Range: -40°C to 1200°C, -40°F to 2200°F
    Accuracy: ±(0.5%rdg+1°C)
    ±(0.5%rdg+2°F), (not including thermocouple error)
    Resolution: 0.1°C on -40°C to 999.9°C
    1°C on 1000°C to 1200°C
    0.1°F on -40°F to 999.9°F
    1°F on 1000°F to 2200°F

 3 phase meter,337 fluke,ac meter,ammeter,ammeters,amp meter,amp meter digital,ampere meter,analog meter,analog multimeter,analoge multimeter,analoges multimeter,analogue multimeter,clamp,clamp current,clamp meter,clamp meter ac dc,clamp meter digital,clamp meter fluke,clamp meters,clamp metre,clamp on meter,clamp on tester,clamp tester,current clamp,current clamp meter,digital clamp meters,digital meter,energy meter,fluke,meter digital,voltmeter




  • Maximum reading of 9999








  • ACA/DCA measurement up to 600.0A








  • Inrush current (100mS) mode, for measuring start current for motors, lighting, etc.








  • Good for PWM trouble shooting and in Noisy environment measurement








  • Improved low current measurement accuracy








  • Temperature Compensation Current sensor








  • HOLD/PEAK HOLD, MAX/MIN, A-Hz and V-Hz function








  • Auto shut-off maximizes battery life








  • Large, backlit display easy to see








  • Dimensions of conductor: O35mm








  • EN61010-1 Approval. Over-Voltage Category CAT III 1000V